4
Technical data
General data and operating conditions
Motor cable length
Maximum motor and feedback cable lengths
(for shielded motor cable with rated mains voltage)
If EMC conditions must be met, the permissible cable lengths can be reduced.
Type
E94xSxE0324
E94xSxE0474
E94xSxE0594
E94xSxE0864
E94xSxE1044
Tab. 4−1
1)
If safety functions with SM301/SM302, which require reliable speed and position detection, are used.
Type
E94xSxE0324
E94xSxE0474
E94xSxE0594
E94xSxE0864
E94xSxE1044
Tab. 4−2
EMC limit value class for conducted noise emission in TN/TT systems:
C2 to EN 61800−3 corresponds to class A to EN 55011
C1 to EN 61800−3 corresponds to class B to EN 55011
1)
Universal−current−sensitive earth−leakage circuit breaker 30 mA
If several devices or cable lengths > 50 m are used, it is possible that the circuit breaker will respond, depending on
the type of cable and the switching frequency.
2)
Universal−current−sensitive earth−leakage circuit breaker 300 mA
If several devices or cable lengths > 50 m are used, it is possible that the circuit breaker will respond, depending on
the type of cable and the switching frequency.
Universal−current−sensitive earth−leakage circuit breaker, cable length £ 25 m: 30 mA, cable length > 25 m: 300 mA,
3)
If several devices or cable lengths > 50 m are used, it is possible that the circuit breaker will respond, depending on
the type of cable and the switching frequency.
4)
See hardware manual, "Fuses and cable cross−sections" chapter.
62
Device size
6
7
Max. shielded motor cable lengths for compliance with the
conducted interference emission according to C1/C2
with RFI filter
2)
E94AZRS0544
50 m/100 m
2)
E94AZRS0954
50 m/100 m
l
[m]
100
100
with mains filter
−
−
EDK94SH104 DE/EN/FR/ES/IT 8.0
without filter
4)
−/50 m
4)
−/50 m