Lenze E94 SHE Single Drive HighLine Série Instructions De Montage page 72

Masquer les pouces Voir aussi pour E94 SHE Single Drive HighLine Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6
Wiring the device
Power terminals
Motor temperature monitoring
Terminal X106
SSP94X6106
Terminal data
flexible
with wire end ferrule
Motor brake control (optional)
Terminal X107
SSP94X6107
Terminal data
flexible
with wire end ferrule
72
Labelling
Description
T1
Motor temperature monitoring with PTC element (type−A sensor,
switching performance according to EN 60947−8 for type−A tripping units)
T2
or thermostat (NC contact).
Max. conductor cross−section
2
[mm
]
[AWG]
2.5
12
Labelling
Description
Connection of the motor holding brake
BD1
+ (Lenze: WH)
BD2
− (Lenze: BN)
E94AZHx0101: 24 V DC, max. 5.0 A
Observe correct polarity!
+ / −
Supply voltage for the motor holding brake (18 ... 30 V DC)
Observe correct polarity!
Max. conductor cross−section
2
[mm
]
[AWG]
2.5
12
l
Tightening torque
[Nm]
[lb−in]
0.5 ... 0.6
4.5 ... 5.3
Tightening torque
[Nm]
[lb−in]
0.5 ... 0.6
4.5 ... 5.3
EDK94SH104 DE/EN/FR/ES/IT 8.0
!
Slot
0.6 x 3.5
!
Slot
0.6 x 3.5

Publicité

Table des Matières
loading

Table des Matières