INSTALLATION REQUIREMENTS
Electrical system requirements
CIRCUIT - Individual, properly polarized and grounded 15
amp. branch circuit fused with 15 amp. time delay fuse
or circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt single phase,
60 Hz, Alternating Current.
NOTE
Because of potentially inconsistent voltage capabilities,
the use of this washer with power created by gas powered
generators, solar powered generators, wind powered
generators or any other generator other than the local
utility company is not recommended.
OUTLET RECEPTACLE - Properly grounded 3-prong receptacle
to be located so the power supply cord is accessible
when the washer is in an installed position.
Grounding type
Grounding type
wall receptacl
wa
ll receptacle
Po Power cord with
wer cord with
3-prong
3-prong gr grounded plug
ounded plug
NOTE
GFI (Ground Fault Interrupter) receptacle is not required.
4
Do not, under
Do not,
under
an any cir
y circumstances,
cumstances,
cut, remo
cut,
remove ve,
or bypass th
or b
ypass the
gr grounding pr
ounding prong.
ong.
Ground requirements
WARNING
ELECTRICAL SHOCK HAZARD
Improper connection of the equipment grounding conductor
can result in a risk of electrical shock. Check with a licensed
electrician if you are in doubt as to whether the appliance is
properly grounded.
1 The washer MUST be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electrical shock by a path of least resistance for
electrical current.
2 Since your washer is equipped with a power supply
cord having an equipment-grounding conductor and
a grounding plug, the plug MUST be plugged into an
appropriate, copper wired receptacle that is properly
installed and grounded in accordance with all local codes
and ordinances or in the absence of local codes, with the
National Electrical Codes, ANSI/NFPA 70 (latest edition).
If in doubt, call a licensed electrician. DO NOT cut off
or alter the grounding prong on the power supply cord.
In situations where a two-slot receptacle is present, it is
the owner's responsibility to have a licensed electrician
replace it with a properly grounded three prong
grounding type receptacle.
Water supply requirements
Hot and cold water faucets MUST be 3/4 inch with threading
for laundry hose connection. Water pressure MUST be
between 30 and 120 psi. Pressure difference between hot and
cold cannot be more than 10 psi. Your water department can
advise you of your water pressure.