Quick start guide
English
KEY
1
Before Using the Flue Gas Analyzer
WARNING!
Be sure all connections are tight to assure accurate sampling.
When conducting measurements, the water trap/filter assembly MUST be in a
VERTICAL position.
These operating instructions describe the basic handling of the device.
Please refer to the operating instructions available at www.sauermanngroup.com
for safe use of the product and detailed information.
Do not give this device to a child.
The magnets in the back of the instrument can damage credit cards, hard drives,
mechanical watches, pacemakers, defibrillators and other devices proven sensitive
to magnetic fields. It is recommended to keep the instrument at a distance of at
least 25 cm (10") away from any of these devices.
These gas analyzers are designed to measure flue gases exhausting from
combustion equipment. They are not designed for continuous operations and/or
use as a control/alarm system
FUNCTION
Turn the instrument on/off
Down key, navigate throught the menu
Up key, navigate throught the menu
Confirm selection
Enter main menu and/or back to previous screen
Water trap OK
When testing is completed, always drain any accumulated condensation
inside the water trap (after EVERY test!).
The condensate be slightly acidic, so avoid contact with skin and make sure
condensate does not leak out of water trap.
Water trap NOT OK