• Remove the four screws that hold the water cover
chamber and inspect the impeller rotor assembly.
• If your rotor assembly impeller and internal pump body
have excessive scale build-up, clean with a mild acid, such
as white vinegar or non-abrasive calcium, lime and rust
remover product using a sponge or soft-bristled brush that
won't scratch the stainless steel. Removing scale build-up
will allow your pump to run like new again.
Replacing the Impeller/Rotor Assembly
When replacing the
AquaForce
rotor-impeller
®
assembly into the pump
chamber, note the proper
orientation. The raised key
on the impeller face plate
should be lined up with the
groove in the pump housing.
PUMP FLANGE PIN
• AquaForce
ready for reassembly – The water chamber
®
cover will only fi t back onto the pump with the top of the
tear-drop shapes lining up, along with matching the hole in
the cover with the pin on the face of the pump motor fl ange.
PUMP
FLANGE PIN
8
GROOVE
RAISED KEY
PUMP WATER
COVER HOLE
PUMP WATER
COVER HOLE
US 1-866-877-6637 |
Replacing Pump in Cage
• Replace the pump into the lower cage and secure in
place with the brackets. Also replace the power cord in
the strain relief
• Reinstall fi lter cage and close all 5 snaps.
Winter Storage
• The pump can be run during freezing weather if desired
but should be removed if shutting down the pump for the
winter. Disconnect the threaded collar on the discharge
fi tting and remove the pump from the pond (be careful
not to lose the fl at rubber washer). Clean the pump and
cage screens with fresh water and store the pump in a
frost-free location.

Troubleshooting

• Reduced Water Flow
– Pump or plumbing may be clogged. It may be necessary
to clean the pump cage screens and impeller.
• Pump Hums and Doesn't Push Water
– Pump or plumbing may be clogged. It may be
necessary to clean the pump cage screens and impeller.
– Remove the water chamber cover and inspect and clean
the impeller rotor assembly and internal pump body.
– Make sure nothing is blocking or wrapped around the
impeller.
– Make sure the pump is receiving the correct voltage.
• Pump Not Working
– The ground-fault circuit-interrupter (GFCI) may
have tripped.
– The pump is not receiving the correct voltage.
• Remote Control Not Working
– Check to make sure the switch located on the Receiver
is in the Remote Control position.
– Check the label on the back of the Receiver and
transmitter to make sure they are paired to the
same frequency.
– Check to make sure the remote control battery is
installed properly. Replace battery if needed.
For more information about our company or products,
please visit our website at www.aquascapeinc.com
or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426.
©2014 Aquascape, Inc. • All Worldwide Rights Reserved
CAN 1-866-766-3426 | www.aquascapeinc.com
91104.11367

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

91104

Table des Matières