Winter Application

• If running through winter conditions, check regularly to make sure it is functioning properly and ice is not preventing water
from reaching the pump. In the event of a power failure, the pump should be removed to prevent any freeze damage to the
pump or the piping.
• If concerned about possible freeze damage, disconnect and remove the pump. Be careful not to lose the flat rubber washer.
Clean with fresh water and store the pump in a frost-free location. If needed, use Aquascape Pump Cleaner Maintenance
Solution (#91143) to remove excessive buildup.

Troubleshooting

• Reduced water flow
– Check the outer and inner filter screens
• Pump hums but doesn't push water
– The pump or plumbing may be clogged
∙ Make sure nothing is blocking the intake
∙ Clean the inner and outer screens
∙ Clean the impeller rotor assembly and internal pump body
– Make sure the pump is receiving the correct voltage
– Make sure the impeller blades are not worn or damaged
• Pump not working
– Ground fault circuit interrupter (GFCI) may have tripped
– The pump is not receiving the correct voltage
• Device won't pair
– Make sure the outlet is receiving power
– Make sure you have adequate wireless coverage to connect the device
– Reset the device to factory defaults
– Make sure the ground fault circuit interrupter (GFCI) is not tripped