Télécharger Imprimer la page

RIB RAPID N Mode D'emploi page 29

Masquer les pouces Voir aussi pour RAPID N:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EMERGENCY RELEASE
Carry out only after power supply to the motor has been interrupted!
In the event of a power supply failure, release the gearmotor, so that you can move the
boom by hand.
To do so, use the RIB key supplied and turn it in the clockwise sense, until the stop is
reached (Pic. 12).
By doing so, the barrier boom works independent from the gearmotor and it can be moved
by hand.
When power is supplied again, turn the key counterclockwise strongly until you block it.
MAINTENANCE
To be undertaken only by specialized staff after disconnecting power supply.
After every 100.000 cycles check:
- boom balance (see the paragraph "ADJUSTING THE BALANCING SPRINGS");
- the tightness of the release knob (see the paragraph "EMERGENCY RELEASE");
- the tightness of the boom holding attachment and the implantation of the boom (see the
paragraph "ASSEMBLING THE BOOM");
- the wear on the mechanical stops and the limiti switch setting (see the paragraph "LIMIT
SWITCH SETTING").
- Grease the bearings of the boom carrier shaft and the threaded spring guide bar.
The described maintenance is vital for the corrected operation of the product in
the time.
ELECTRIC CONNECTIONS
POINT A - CONTROL PANEL FEATURES
J4
J1
S3
TR2
J9
J5
J2
J3
J1
J2
J8
J3
J4
J5
J7
J6
J7
J6
J8
J9
J10
J10
S3
TR2
L-N
Main power supply 230Vac 50/60Hz upon request)
COM
Common contact
LSC
Closing limit switch contact (NC)
LSO
Opening limit switch contact (NC)
LSSC
Closing slowing down limit switch contact (NO)
LSSO
Opening slowing down limit switch contact (NO)
TLC
Vehicle presence signal (NO) (only when switched to PARK mode)
PHOT. NC
Photocells contact (NC)
EDGE NC
Safety strip contact (NC)
COM
Common contact
D+ TEST
Safety strip self-test power supply +12Vdc 500mA max
D+
Accessories power supply +12Vdc 500mA max
D-
Accessories power supply -12Vdc 500mA max
OPEN 2
Barrier opening button 2 contact (NO) (only when switched to PARK mode)
SIGNAL
Barrier open signal 12Vdc
Buzzer - Acoustic signal connection (12Vdc max 200 mA)
AERIAL
Radio antenna
Blinker (max 40W)
U - MOTOR
Motor common connection
V-W - MOTOR
Motor inverters and condenser connection
Immediate closure command contact (only when switched to PARK mode)
OK CLOSE
Open1 button contact (NO)
OPEN 1
CLOSE
Close button contact (NO)
STOP
Stop button contact (NC)
K BUTT.
Single pulse button (NO)
COM
Common contact (common line for all the commands and safety inputs)
PROBE
Heating probe connection terminal block (code ACG4666 optional)
RADIO
Built in radio module
AUX. ATT.
Card 1 relay connector (code ACQ9080) for management of courtesy light
or boom arm locking magnet
Card 3 relay connector (code ACQ9081) for management of courtesy light
or boom arm locking magnet and traffic lights.
SW PARK
DO NOT TOUCH THE JUMPER!
IF REMOVED THE OPERATOR DOES NOT FUNCTION!
SW RADIO
DO NOT TOUCH THE JUMPER!
IF REMOVED THE RADIO SYSTEM DOES NOT FUNCTION!
PROG.
Programming button
TRIMMER LOW SPEED
Slow closure speed electronic regulator
PARK CRX
code AC07063
G
B
12

Publicité

loading

Ce manuel est également adapté pour:

Rapid n metalAa50080fAa50083f