2.0 Installation
·
First, remove the wallplate from the back of the unit.
·
From the top left hand corner of the wallplate, there must be
clearances of at least 150mm to the right, 15mm to the left,
30mm above and 100mm below in order to mount the plug-in
module.
·
Fix at a height of approximately 1.5m from the fl oor, away from
draughts or heat sources such as radiators, open fi res or direct
sunlight.
2.1 Thermostat Wiring (Hard wired model only)
N/C
N/O
1
2 3
OFF
COM
!
Some existing thermostats will have a Neutral and/or Earth wire
connected. These are not required by the TP4000 and must NOT be
connected to any TP4000 terminals. Instead they should be made
electrically safe and coiled in the recess at the back of the TP4000.
Danfoss Heating
ON
GB
GB
FR
ES
NL
GR
PL
CZ
TR
HR
RO
HU
LT
5