Installation Instructions; Product Specification - Danfoss TP5001 Série Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 63

Installation Instructions

GB
Please Note:
This product should only be installed by a qualifi ed electrician
or competent heating installer and should be in accordance
with the current edition of the IEEE wiring regulations.
Product Specifi cation
Thermostat features
Power supply
Memory back-up
Temperature Range
Sensing
Factory set calendar clock
Switching action of
output relay
Transmission frequency
(RF models)
Transmission range
(RF models)
Remote sensor inputs
(A models only)
Dimensions (mm)
Design standard
Rated impulse voltage
Ball hardness test
Control pollution
situation
Temperature accuracy
Time accuracy
Important note RF products: Ensure that there are no large metal objects, such as boiler cases
or other large appliances, in line of sight between the transmitter and receiver as these will
prevent communication between thermostat and receiver.
2
TP5001 (A)
2 x AA/MN1500/LR
alkaline cells
Retained for life of product
Automatic summer/winter time change
3(1)A,
10-230V
N/A
N/A
Can be set by installer for remote temperature sensor,
limit sensor, window contact or telephone activated
110 wide, 88 high, 28 deep
EN60730-2-9 (EN300220 for RF)
±1 min. per month
TP5001-RF
5-30°C
N/A
3(1)A, 10-230V,
433.92MHz
30m max.
switch contacts
2.5kV
75°C
Degree 2
±1°C
TP5001M (A)
230V, ±15%,
50Hz
Type 1B
N/A
N/A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tp5001 aTp5001-rfTp5001m a

Table des Matières