6. APPENDIX
6. Interface drawing
#ONTROLLER INTERFACE DIAGRAM AND DElNITION
CN9
Main board of the input and output interface instructions below
NUMBER SIGN
01
OUT 1
02
OUT 2
03
OUT 3
04
OUT 4
05
OUT 5
06
AC-L
07
AC-N
08
AI-DI01
09
AI-DI02
10
AI-DI03
11
AI-DI04
12
AI-DI05
13
AI-DI06
14
AI-DI07
15
AI-DI08
16
AI-DI09
17
AI-DI10
18
AI-DI11
19
AI12(50K)
20
0_5V_IN
21
PWM_IN
22
PWM_OUT
23
0_10V_OUT
AC-N
OUT3
OUT5
OUT4
PC1002
MEANING
Compressor (output 220-230VAC)
Water pump (output 220-230VAC)
4-way valve (output 220-230VAC)
High speed of fan (output 220-230VAC)
Low speed of fan (output 220-230VAC)
Live wire (output 220-230VAC)
Neutral wire (output 220-230VAC)
Emergency switch (input)
WATER mOW SWITCH INPUT
System low pressure (input)
System high pressure (input)
System suction temperature (input)
Water input temperature (input)
Water output temperature (input)
System fan coil temperature (input)
Ambient temperature (input)
Mode switch (input)
Master-slave machine switch / Antifreeze temperature (input)
System Exhaust temperature (input)
Compressor current detection / Pressure sensor (input)
Master-slave machine switch / Feedback signal of EC fan (input)
AC fan control (output)
EC fan control (output)
OUT1
AC-L
OUT2
GND
485_B1
485_A1
12V
GND
485_B2
485_A2
12V
21