2. SPECIFICATION
REFRIGERANT : R410A
UNIT
*Ratedheating power input (95 Hz)
*Range
*Rated running current input (95 Hz)
*Range
**Rated heating power input (95 Hz)
**Range
**Rated running current input (95 Hz)
**Range
Power supply
Compressor quantity
Compressor
Fan quantity
Fan power input
Fan rotate speed
Fan direction
Noise
Water connection
WATER mOW VOLUME
Water pressure drop (max)
Unit net dimensions (L/W/H)
Unit ship dimensions (L/W/H)
Net weight
Shipping weight
Rated heating
*Outdoor air temp : 80.6°F (27°C) / 75.8°F (24.3°C), Inlet/Outlet water temp : 80°F (26.7°C) / 84.7°F (29.3°C)
**Outdoor air temp : 59°F (15°C) / 53.6°F (12°C), Inlet/Outlet water temp : 78.8°F (26°C) / 82.4°F (28°C)
During heating : running ambient temperature : 23°F (-5°C) - 109.4°F (43°C)
Visit www.ahridirectory.org for full Distinction Heat Pump Performance Data
PASRW050-BP2
kW
4.03
kW
0.29 - 4.03
A
17.5
A
1.26 - 1.75
kW
3.70
kW
0.48 - 3.70
A
16.1
A
2.08 - 16.1
208-230V - 60 Hz
1
Rotary
1
W
100
RPM
500 - 750
Horizontal
dB (A)
45 - 57
Inch
1.5
g/min
27.3
kPa
6
Mm
See the drawing of the units
Mm
See package label
Kg
See name plate
Kg
See package label
3