2. SPECIFICATION
2.1 Performance data of swimming pool heat pump unit
REFRIGERANT : R410A
UNIT
*Rated heating power input (95 Hz)
*Range
*Rated running current input (95 Hz)
*Range
**Rated heating power input (95 Hz)
**Range
**Rated running current input (95 Hz)
**Range
Power supply
Compressor Quantity
Compressor
Fan quantity
Fan power input
Fan rotate speed
Fan direction
Noise
Water connection
Water flow volume
Water pressure drop (max)
Unit net dimensions (L/W/H)
Unit ship dimensions (L/W/H)
Net weight
Shipping weight
Rated heating
*Outdoor air temp : 80.6°F (27°C) / 75.8°F (24.3°C), Inlet/Outlet water temp : 80°F (26.7°C) / 84.7°F (29.3°C)
**Outdoor air temp : 59°F (15°C) / 53.6°F (12°C), Inlet/Outlet water temp : 78.8°F (26°C) / 82.4°F (28°C)
During heating : running ambient temperature : 23°F (-5°C) - 109.4°F (43°C)
Visit www.ahridirectory.org for full Distinction Heat Pump Performance Data
2
PASRW030-BP2
kW
2.32
kW
0.25 - 2.32
A
10.0
A
1.08 - 10.0
kW
2.15
kW
0.29 - 2.15
A
9.34
A
1.26 - 9.34
208-230V - 60 Hz
1
Rotary
1
W
100
RPM
500-650
Horizontal
dB (A)
43 - 53
Inch
1.5
g/min
18.0
kPa
4
Mm
See the drawing of the units
Mm
See package label
Kg
See name plate
Kg
See package label
PASRW040-BP2
3.13
0.24 - 3.13
13.6
1.04 - 13.6
2.77
0.35 - 2.77
12.0
1.52 - 12.0
208-230V - 60 Hz
1
Rotary
1
100
500 - 700
Horizontal
44 - 54
1.5
22.9
5