WARNING
The products described in this manual are kerosene
direct-fired, forced air heaters. Kerosene forced air
heaters are primarily intended for use for temporary
heating of buildings under construction, alteration or
repair. Direct-fired means that all of the combustion
products of the heater enter the heated space. This
appliance is rated at 98% combustion efficiency, but
does produce small amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate only
small amounts of carbon monoxide and so precautions
should be taken to provide proper ventilation. Failure
to provide proper ventilation in accordance with the
instructions in this manual can result in death.
People with breathing problems should consult a phy-
sician before using this heater.
Early signs of carbon monoxide poisoning resemble
the flu. Symptoms of improper ventilation / carbon
monoxide poisoning are:
DANGER
Headache • Dizziness • Nausea • Dry Mouth Sore
Throat • Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater serviced
and check for proper ventilation. Some people are
more affected by carbon monoxide than others. These
include: pregnant women, those with heart or lung
problems, anemia or those under the influence of alco-
hol or at high altitudes.
Not For Indoor Use. Indoor use permitted only for
the temporary heating of buildings under construc-
tion, alteration or repair!
Provide at least a three square foot (2,800 sq cm)
opening of outside air for every 100,000 Btu/Hr (29
kW) heater rating. Refer to "Ventilation" on page 6
for further instructions.
© 2021 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
SAFETY INFORMATION (CONT.)
RISK OF INDOOR
AIR POLLUTION!
CARBON MON-
OXIDE POISON-
ING MAY LEAD TO
DEATH!
WARNING
ALWAYS use only the electrical power (voltage and
frequency) specified on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and
extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly exposed
to water spray, rain, dripping water, or wind.
NEVER use fuels such as gasoline, benzene, paint
WARNING
thinners or other oil compounds in this heater.
NEVER refill the heater's fuel tank while the heater is
operating or still hot. This heater is EXTREMELY HOT
while in operation.
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
150T-SDR
Top
4 ft. (122 cm)
Sides
4 ft. (122 cm)
Front
8 ft. (244 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it is
plugged in, it can start at anytime in accordance with
the thermostat setting.
WARNING
TOUCH. KEEP CHILDREN, ANIMALS, CLOTH-
ING AND COMBUSTIBLES AWAY FROM HEAT-
ER.
3
Silent Drive Forced Air Heater User's Manual
RISK OF ELECTRIC
SHOCK!
RISK OF BURNS,
FIRE AND EXPLO-
SION!
220T-SDR
4 ft. (122 cm)
4 ft. (122 cm)
8 ft. (244 cm)
CAUTION! HOT
WHILE IN OP-
ERATION. DO NOT