BWT Bewades EU Serie Instructions De Montage Et D'utilisation page 26

Désinfection aux uv
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
6
11
Bewades 80W, 100W
11
Bewades 240W, 320W
26
Bewades 80W und 100W
● Unscrew radiator protection tube retainer (9) and threaded union (7).
● Insert the quartz glass tube (5), ensuring that it engages with the
12
lower guide in the irradiation chamber.
● Slide the O-ring (6) from the bag of accesories onto the quartz glass
9
tube. Screw on the threaded union (7).
● While doing so lift the quartz glass tube approximately 1 mm, then
8
tighten the union securely with the special wrench from the bag of
7
accessories. Make sure that the O-Ring is seated correctly.
● Thighten quartz glass tube fixation (9) with rubber disc (8) by hand.
Do not thighten firmly!
● Insert the radiator (10) and connect it to the plug (11) of the blue cap
(12). Ensure that the plug is correctly seated.
● Screw on the blue protective cap (12) and secure it with two grub
screws.
● Caution! Danger of injury! Never pressurize the unit without retainer
(9) in place!
5
10
Bewades 240W und 320W
● Unscrew and remove the locking screw (7) with the rubber disc (8).
● Slide the O-ring (6) from the bag of accessories about 40 mm onto
12
the upper end of the quartz glass tube (5).
● Insert the quartz glass tube (5), ensuring that it engages with the
lower guide in the irradiation chamber.
8
● Tighten the tensioning screw (7) and support ring (8) hand-tight (with
a small gap between the tensioning screw and the cover of the UV
unit).
7
● Insert the radiator (10) and connect it to the plug (11) of the blue cap
(12). Ensure that the plug is correctly seated.
● Screw on the blue protective cap (12) and secure it with two grub
6
screws.
● Caution: for saftey reasons, the UV radiators may be switched on
5
only within the unit and with the blue protective cap (12) fitted.
10
6
5
6
5

Publicité

Table des Matières
loading