Télécharger Imprimer la page

Chauvet DJ Geyser T6 Manuel De Référence page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
EN
AC Power
This product has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
Fuse Replacement
1.
Disconnect the product from power.
2.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3.
Pry the safety cap out of the housing.
4.
Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same
type and rating.
5.
Re-insert the fuse holder and reconnect power.
Control Panel Description
BUTTON
FUNCTION
<MENU>
Exits from the current menu or function
<UP>
Navigates upwards through the menu list and increases the numeric value when in a function
<DOWN>
Navigates downwards through the menu list and decreases the numeric value when in a function
Enables the currently displayed menu or sets the currently selected value into the selected
<ENTER>
function
Menu Map
MODE
MAIN LEVEL
Manual Button
Color/Program
FC-W Color/
Program
Temperature
3
QUICK REFERENCE GUIDE
PROGRAMMING LEVELS DESCRIPTION
CoLo
CH-1
P1 0–16
CH-2
P2 0–16
CH-3
P3 0–16
CH-4
P4 0–16
Ht
P 0
No color
P 1
Red
P 2
Green
P 3
Blue
P 4
Yellow
P 5
Magenta
P 6
Cyan
P 7
White
P 8
Red strobe
P 9
Green strobe
P 10
Blue strobe
P 11
Yellow strobe
P 12
Magenta strobe
P 13
Cyan strobe
P 14
White strobe
P 15
Auto fade
P 16
Auto snap
Selects button 1 color/program
Selects button 2 color/program
Selects button 3 color/program
Selects button 4 color/program
_ _ _
Displays current heater temperature
Geyser T6 QRG Rev. 1

Publicité

loading