Chart 1 - Air Caps; Chart 2 - Fluid Nozzles & Fluid Needles - DeVilbiss TEKNA PROLITE 703536 Fiche Technique

Pistolet professionnel à vaporiser alimenté par pression, ensemble de réparation
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Parts Replacement/Maintenance
Chart 1 – Air Caps
ORDER NO. FOR
TECHNOLOGY
AIR CAP
703621
HVLP
703539
High Efficiency
703626
High Efficiency
NOTE 1: Guns with HVLP caps must not exceed 0.7 bar (10 psi) air cap pressure with
gun fully triggered. (Aproximately 17 psi gun inlet pressure.) (See accessories
for air cap test kit which is available to set the exact cap pressure.)
When used with high efficiency caps and Automotive Refinishing materials,
these spray guns have been found to exceed 65% transfer efficiency under
recommended conditions.
NOTE 2: When removing air cap from retaining ring, don't remove slip ring (2)
or retaining ring seal (5) from retaining ring. Damage to the parts may
occur. Slip ring and retaining ring seal are not available as replacements.
Simply wipe parts clean and reassemble with new or clean air cap.
Chart 2 – Fluid Nozzles & Fluid Needles
ORDER NO. FOR
PART NO. ON
FLUID NOZZLE
FLUID NOZZLE
703627
PRO-205-10
703628
PRO-205-12
703622
PRO-205-14
NOTE: When replacing the fluid nozzle or fluid needle, replace both at the same time.
Lightly lubricate the threads of the fluid nozzle before reassembling. Torque
to 18–20 Nm (13–15 ft-lbs). Don't over tighten the fluid nozzle. Use 10 mm
wrench supplied with gun.
MARKING
NOMINAL
ON AIR CAP
OPERATING GUN
INLET PRESSURE
BAR/PSI
HV40
(1.2) / 17
(for compliance)
TE20
(1.8 – 3.5) / 26 – 50
TE40
(2.0 – 3.5) / 29 – 50
PART NO. ON
ORDER NO. FOR
FLUID NEEDLE
FLUID NEEDLE
PRO-320-085-10
703629
PRO-320-12-14
703623
AIR FLOW
LPM/SCFM
(298) / 10.5
(340 – 550) / 12 – 19.4
(368 – 550) / 13 – 19.4
TB-1014-B
11

Publicité

Table des Matières
loading

Table des Matières