3. Technical data
The CO-detector is calibrated so that it sounds in
response to the following CO-values, in compliance
with EN 50291-1:2010 + A1:2012.
CO concentration No alarm
in the air
30 ppm
50 ppm
100 ppm
300 ppm
Protection class:
Power :
Max. current:
Sound level of signal: 85 dB (1 m distance)
Battery life:
Device service life:
ATTENTION:
IMPORTANT!
THIS IS NOT A SMOKE ALARM! This CO-detector
was developed to detect carbon monoxide coming
from ANY combustion source. It was NOT
developed to detect smoke, fire or other gases.
Operating Instructions
before
120 min.
60 min.
10 min.
-
IP 20
9 Volt DC alkaline battery
(IEC 6LR61) or MN1604
< 40 mA (alarm)
Min. 1 year
approx. 6 years
Alarm
before
-
90 min.
40 min.
3 min.