AXIS P13-E Network Camera Series
Note
• The weight of the camera is 3000 g (6.6 lb). Check that the material is strong enough to
support this weight.
• Using any other than the provided cable gland may cause water to seep in and damage
the product.
• Always use a shielded network cable (STP) intended for outdoor use between the
Axis product and the end point and ensure that the end point is properly grounded.
Installations of Axis products using a shielded network cable (STP) and a properly
grounded end point have been tested to comply with industry immunity standard levels
such as surge protection. Any other installation method will void the warranty and
leave the unit at a risk.
1. Use the supplied drill template to prepare a wall or pole for installation of the wall
bracket.
2. Route the network cable through the wall bracket, and through the bracket adapter.
Leave approximately 30 cm (11.8") of cable for connecting to the camera.
3. Install the wall bracket on a wall, ceiling, or pole using screws and plugs appropriate for
the material (e.g. wood, metal, sheet rock, stone).
NO
NO TICE
NO
TICE
TICE
For more technical specifications, see User Manual available at www.axis.com
Do the following to route the network and other (optional) cables:
1. Loosen the cable cover screws; detach the cable cover from the bottom cover.
2. Remove the cap, the plug and the gasket from the cable gland to be used.
3. Route the network cable through the cap.
4. Slide the network cable through the slit in the gasket.
5. Route the network cable through the cable gland.
6. Press the gasket into the cable gland and screw the cap on firmly.
Note
Using any other than the provided cable gland may cause water to seep in and damage the
product. Cables must have a diameter of 4.0 mm —5.5 mm.
Do the following to attach the camera to the wall bracket:
1. Place the camera with the bottom cover on the wall bracket and tighten the bracket
screws
2. Replace the cable cover and tighten the screws.
3. Connect the cables. See page 19
4. Loosen the bracket adjustment screw to focus the camera; focus the camera according
to the instructions under Adjust Focus on page 19