Grounding installation
This appliance is classified as protection class I
and must be connected to a protective ground.
Grounding reduces the risk of electric shock by
providing an escape wire for the electric current.
Preparation before using for the first time
• Remove all protective packaging and wrapping.
Make sure no packaging debris remain on or in-
side the appliance.
• Check for completeness (4 trays, 1 tray handle
and 1 water pipe are included) and any transport
damage. In case of damages or incomplete deliv-
ery, please contact supplier (See --- > Warranty
page).
• Keep the packaging for storing your appliance
when not in use for an extended period of time.
• Place all the trays & the tray handle inside.
• Connect the power plug to a suitable electrical
wall outlet.
• Select the following settings for the first time us-
ing.
Control
Temp control
Timer control
Electric diagram
Setting
300°C
10 minutes
This appliance is equipped with a cord having a
grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly in-
stalled and grounded.
• The Temp control indicator
dicator
and the internal light of the appliance
are all lights up.
Note: Due to the manufacturing residues, the
appliance may emit a slight odor in the first few
cycles. This is normal and does not indicate any
defect or hazard. Make sure the appliance is well
ventilated.
• When the set time ends, the appliance tempera-
ture and timer indicators goes off.
• Allow the appliance to cool down completely and
clean it afterwards (See ---> Cleaning and main-
tenance).
TEMP. limit control
Timer
Power indicator
Chamber illumination light
Door switch
Fans
Thermostat
Temperature indicator
Heating elements
Steam switch
Steam indicator
Solenoid
, Timer control in-
EN
5