ENGLISH
cordless power tools:
Switch off and unplug the appliance/tool.
u
Or switch off and remove the battery from the appliance/
u
tool if the appliance/tool has a separate battery pack.
Or run the battery down completely if it is integral and then
u
switch off.
Unplug the charger before cleaning it. Your charger does
u
not require any maintenance apart from regular cleaning.
Regularly clean the ventilation slots in your appliance/tool/
u
charger using a soft brush or dry cloth.
Regularly clean the motor housing using a damp cloth. Do
u
not use any abrasive or solvent-based cleaner.
Regularly open the chuck and tap it to remove any dust
u
from the interior (when fitted).
Mains plug replacement (U.K. & Ireland only)
If a new mains plug needs to be fitted:
Safely dispose of the old plug.
u
Connect the brown lead to the live terminal in the new
u
plug.
Connect the blue lead to the neutral terminal.
u
Warning! No connection is to be made to the earth terminal.
Follow the fitting instructions supplied with good quality plugs.
Recommended fuse: 5 A.
Protecting the environment
Separate collection. Products and batteries
marked with this symbol must not be disposed of
with normal household waste.
Products and batteries contain materials that can be recov-
ered or recycled reducing the demand for raw materials.
Please recycle electrical products and batteries according to
local provisions.
Further information is available at www.2helpU.com
Technical data
Input voltage
V
AC
Power input
W
No load speed
min
-1
Max. drilling capacity
Concrete
mm
Steel
mm
Wood
mm
Weight
kg
8
(Original instructions)
BEHS02
0 - 1200
Declared dual-number noise emission values in
accordance with ISO 4871
Measured A-weighted sound power level, L
Uncertainty, K
Measured A-weighted emission sound pressure level at the work
station, L
Uncertainty, K
Values determined according to noise test code given in EN
using the basic standards EN 60745-2-6:2010
NOTE - The sum of a measured noise emission value and its
associated uncertainty represents an upper boundary of the
range of values which is likely to occur in measurements
Vibration total values (triax vector sum) determined
Vibration
emission Value a
Uncertainty K
Values determined according to EN 60745-
1:2009+A11:2010 and EN 60745-2-6:2010
EC declaration of conformity
Black & Decker declares that these products described
230
under "technical data" are in compliance with:
EN60745-1:2009+A11:2010, EN60745-2-6:2010.
800
These products also comply with Directive 2006/42/EC,
2014/30/EU and 2011/65/EU.
For more information, please contact Black & Decker at the
22
following address or refer to the back of the manual.
13
30
3.2
WA
decibels = 106.5 dB(A)
, in decibels = 3 dB(A)
WA
(ref. 20μPA), in decibels = 95.5 dB(A)
PA
, in decibels = 3 dB(A)
PA
60745-1:2009+A11:2010,
according to EN 60745
the work mode
description
'hammer drilling
into concrete'
18.7 m/s
2
h
1.5 m/s
2
MACHINERY DIRECTIVE
BEHS02 Impact drill
(ref. 1pW), in
the work mode
description
'chiselling'
17.6 m/s
2
1.5 m/s
2