Télécharger Imprimer la page

Broan ALLURE QSE1 Serie Manuel D'instructions page 3

Publicité

Les langues disponibles

Les langues disponibles

PREPARE THE HOOD
DAMPER/DUCT
CONNECTOR
3
Remove Damper/Duct Connector from inside the hood.
Set connector aside - with mounting screws and parts
bag.
WIRING
COVER
Remove Wiring Cover from inside the hood. Set cover
4
and mounting screw aside.
5
Remove either top or back wiring knockout and install ap-
proved Electrical Cable Clamp.
PREPARE THE HOOD
TOP RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼" x 10"
Vertical Discharge)
RECTANGULAR
DUCT KNOCKOUT
(Remove for 3¼" x 10"
Horizontal Discharge)
6
UP TO 1"
SIDE-TO-SIDE
ADJUSTMENT
PIVOT
7
NOTE
ELECTRICAL
CABLE CLAMP
ALLURE
REAR
Remove appropriate Duct Knockout(s) from top or back of
hood.
TAPE
3¼" x 10" Ducted Discharge Only: Attach Damper/Duct
Connector over knockout opening. Make sure damper Pivot
is nearest to Top/Back Edge of hood. Remove Tape from
damper flap.
Damper/Duct Connector can be installed up to 1-inch
on either side of hood center to accomodate off-center
ductwork. In extreme off-center installations, one end
of the duct connector may need to be trimmed to clear
the electrical cable clamp.
QSE1 SERIES
®
RANGE H OOD
Page 3
TOP/BACK
EDGE
DAMPER/DUCT
CONNECTOR
(Vertical discharge
position shown)

Publicité