thuba MS16 Manuel page 5

Table des Matières

Publicité

Manual PTB 20 ATEX 1012
2.
Conformity with Standards
The magnetic switch MS16 and small thermostat
ST16 meet the requirements of IEC 60079-0,
IEC 60079-1 and IEC 60079-31. They were
developed, manufactured and tested in accor-
dance with ISO 9001:2015.
3.
Technical Data
3.1 Marking
II 2G Ex db IIC T6 Gb
II 2D Ex tb IIIC T80°C Db
I M2
Ex db I Mb
3.2
Certification
3.2.1 EU Type Examination Certificate
PTB 19 ATEX 1012
3.2.2 IECEx Certificate of Conformity
IECEx PTB 20.0022
3.3
Permissible ambient temperatures
The explosionproof magnetic switch MS16 and
small thermostats ST16 have been designed for
an ambient temperature of –20 °C to 40 °C
(standard) or –60 °C to 75 °C (on request).
3.5
Electrical Data
Contact
Terminal cross section 3 x 0.75 mm²
Cable length
4.
Installation
The generally recognized rules of engineer-
ing, IEC 60079-14 'Electrical installations
design, selection and erection', national reg-
ulations and the instructions set out in this
manual apply for the installation and opera-
tion.
Edition January 2021
Copyright
250 V AC 2.5 A AC-21
24 V DC 1.5 A DC-21
min. 1 m
thuba Ltd., CH-4002 Basel
Switzerland
5

Publicité

Table des Matières
loading

Table des Matières