Télécharger Imprimer la page

EUROM HKG 15-BE Manuel D'utilisation page 25

Publicité

Les langues disponibles

Les langues disponibles

Attention!
If you have tried to start the device according to the procedure described above
and that does not work after three attempts to ignite it, don't try it again. Due to
the high gas concentration, there is now an explosion hazard! Contact your dealer
to find out the reason for the malfunction.
Make sure when you install the gas bottle that the gas hose is not bent or kinked.
Avoid twisted and tensile stress. This can damage it and gas leakage can occur!
Always use the correct, supplier-provided pressure regulator and gas hose.
If you have questions about the gas hose, contact your supplier. A length of 1.5
metres is advised.
Gas leakage test
To rule out the possibility of damage during transport or due to high pressure, wear
and tear, etc., a complete gas leakage test must be performed during installation,
after changing a gas bottle and after a period of storage. All leakage inspection
must be performed with a soap solution, never with fire! Do not smoke
during the inspections. When there is gas leakage, immediately close the gas tap
on the gas bottle (be alert for the odour!) and remove the equipment far from other
sources of heat, fire and sparks.
 Perform the inspection with a
full gas bottle.
 Unplug
it,
switch
switch to O (off), close the gas
supply.
 Make a soap solution with one
part liquid soap and one part
water.
 Apply the soap solution to the
entire
gas
transport
especially on the connections,
with a spray bottle, brush or
cloth.
 Open the gas supply. If there is a leak, you will see soap bubbles.
 If there is a leak, switch off the gas supply. Tighten the leaking part, turn on the
gas supply again and check again. If there are still bubbles, contact your
supplier.
 Make sure there is no fire or sparks in the vicinity when you are performing the
leakage test and do not smoke!
 If the gas hose shows signs of bursting, cracks or other damage, it must be
replaced by a new hose of the same length and equivalent quality. Replace it at
least every 3 or 4 years; see the writing on the hose.
the
power
system,
25

Publicité

loading

Ce manuel est également adapté pour:

322231