Instructions for use
Uk
Read the instructions for use carefully, especially the safety instructions. Failure to observe these instructions for use may result in serious injury or
damage to the product.
!
Important note in advance (only JBL PROFLORA CO₂ PROFESSIONAL U-, M-, or V SET)
Please don't forget to buy a new JBL PROFLORA CO₂ pH SENSOR SET!
To guarantee you the highest reliability when using the JBL PROFLORA CO₂ CONTROL contained in the systems above, the systems are sold without
a pH sensor. When purchasing the device make sure to also purchase a new pH SENSOR SET. Your specialist pet shop will have one in stock for you.
Dear Customer,
Congratulations on your purchase of this ultramodern JBL PROFLORA CO₂ system from SYSTEM U- M- or V. Whether with disposable or
refillable CO₂ pressurised gas cylinders, precise and easy-to-use technology ensures a convenient and safe supply of CO₂ to your aquarium. This will
give you beautiful and vibrant aquarium plants almost in no time at all.
Differentiating between the systems and sets:
SYSTEM BIO: CO₂ gas is produced from biological fermentation processes.
SYSTEM M: Reusable CO₂ pressurised gas cylinders with thread W21.8 x 1/14" are refillable.
SYSTEM U: Disposable CO₂ pressurised gas cylinders with thread M10x1 are not refillable.
SYSTEM V: VARIO sets do not contain CO₂ pressurised gas cylinders. However, they can be operated with M and U CO₂ pressurised gas cylinders.
Special features of the SYSTEM V:
JBL PROFLORA CO₂ fertiliser systems of SYSTEM V differ in their design in that no CO₂ pressurised gas cylinders are included. All descriptions for
SYSTEM M also apply to SYSTEM V.
Intended use:
The product is designed for use in an aquarium only. The product is to be used indoors only. It is intended for private use only and is not suitable for
commercial use.
Use the product only as described in this instruction manual. Any other use will be deemed inappropriate and may result in property damage or
personal injury. The product is not a child's toy.
2.
Safety instructions
Please read and observe the following safety instructions for a safe and hazard-free handling of the CO₂ pressurised gas cylinders.
Safety instructions:
1. Follow the safety instructions for handling CO₂. These can be found on the CO₂ pressurised gas cylinders.
2. Children must be supervised to ensure that they do not play with the appliance and its power supply unit.
3. Do not use the appliance for any purpose other than that described in these instructions for use.
4. Do not operate or store the unit in places where there is a risk of frost.
5. Appliance may only be used indoors.
6. Appliance may only be used in a dry environment.
Disposal: Do not dispose of this device and the power unit in the normal household waste. Please follow your local disposal regulations for electrical
equipment.
16
3.
Special features
Professional water care:
• Beautiful and vibrant aquarium plants.
• Active algae prevention and healthy fish.
• For both fast and slow growing plants.
Economical:
• CO₂ reactors/diffusers of the JBL PROFLORA CO
TAIFUN range with maximum diffusion rate of CO₂ in water.
2
• Exact dosing using a high-precision fine needle valve at the pressure regulator.
• CO₂ savings from night switch-off with solenoid valve.
JBL PROFLORA CO
PROFESSIONAL SET only:
2
• Digital measuring and control technology JBL PROFLORA CO₂ CONTROL regulates pH value and CO₂ supply reliably and fully automatically.
Convenient:
• Easy to assemble.
• Best monitoring with bubble counter JBL PROFLORA CO₂ TAIFUN COUNT SAFE with integrated backflow protection.
• Refillable reusable CO₂ pressurised gas cylinder JBL PROFLORA CO₂ CYLINDER 500 M (SYSTEM M).
• Convenient disposable CO₂ pressurised gas cylinder JBL PROFLORA CO₂ CYLINDER 500 U (SYSTEM U).
JBL PROFLORA CO
BASIC SET only:
2
• Elegant glass diffuser with ceramic membrane JBL PROFLORA CO₂ TAIFUN GLASS.
From JBL PROFLORA CO
ADVANCED SET onwards:
2
• Pressure regulator with pressure gauges for working and residual pressure display.
• Expandable reactor JBL PROFLORA CO₂ TAIFUN SPIRAL.
JBL PROFLORA CO
PROFESSIONAL SET only:
2
• CO₂/ pH control JBL PROFLORA CO₂ CONTROL with touch display and multilingual user guidance.
Safe:
• Tested refillable CO₂ pressurised gas cylinders JBL PROFLORA CO₂ CYLINDER 500 M with overpressure protection and secure wall mounting
(SYSTEM M).
• Tested disposable CO₂ pressure gas cylinders JBL PROFLORA CO₂ CYLINDER 500 U, free-standing (SYSTEM U).
• With pressure relief valve on the pressure regulator.
• Bubble counter JBL PROFLORA CO₂ TAIFUN COUNT SAFE with integrated non-return valve to protect the pressure regulator against backflowing
water.
• With hose screw connections to prevent the hose from slipping off.
JBL PROFLORA CO
ADVANCED SET and JBL PROFLORA CO
2
• Pre-assembled solenoid valve JBL PROFLORA CO₂ VALVE operated with 12 V safety extra-low voltage.
JBL PROFLORA CO
PROFESSIONAL SET only:
2
• CO₂/pH control JBL PROFLORA CO₂ CONTROL operated with 12 V safety extra-low voltage.
PROFESSIONAL SET only:
2
UK
17