• Check to make sure the pH level is maintained, so that the CO₂ level in the CO₂ permanent test is also correct.
UK
• JBL PROFLORA CO₂ ADVANCED SET: With these systems, the pH control unit takes over the automatic maintenance of the desired pH value.
9.

Note on the pressure displayed on the pressure regulator

In the CO₂ pressurised gas cylinders, the CO₂ gas is under high pressure. This pressure depends on the ambient temperature. At room temperature
(approx. 20 °C), the left pressure gauge of the pressure regulator shows a pressure of about 50 bar. This increases as the room temperature rises.
Thus at 30 °C, the pressure gauge shows about 70 bar. The pressure in the CO₂ pressurised gas cylinder is not a measure of how full the cylinder is.
It will remain constant at the temperature-related value until shortly before the cylinder is empty. How much CO₂ is in a CO₂ pressurised gas cylinder
can only be determined by weighing it. The empty weight (tare) is stamped on the cylinder. The current weight minus the tare gives the available
amount of CO₂.
The pressure in the CO₂ pressurised gas cylinder is regulated down to an easy-to-handle so-called „working pressure" by the pressure regulator. The
right-hand pressure gauge of the pressure regulator shows this working pressure. It is preset to approx. 2 bar in the JBL PROFLORA CO₂ REGULA-
TOR BASIC pressure regulators. When changing the working pressure, it is important that a decrease in CO₂ takes place, i.e. the adjustment screw
must not be closed, otherwise the new working pressure cannot regulate itself.

10. Changing cylinders

If the cylinder pressure on the left-hand pressure gauge falls below 30 bar, the refillable CO₂ pressurised gas cylinder needs to be refilled within
the next 2 - 3 days. The disposable CO₂ pressurised gas cylinder may only be changed when it no longer contains CO₂. This is when both pressure
gauges show 0 bar or no more CO₂ bubbles rise in the aquarium.
Disposable CO₂ pressurised gas cylinder:
Make sure that the disposable CO₂ pressurised gas cylinder is completely empty. There should be no CO₂ bubbles rising in the reactor or diffuser.
Disconnect the CO₂ hose from the pressure regulator fitting and turn the pressure regulator counterclockwise off the Cylinder. Dispose of the empty
cylinder according to your local regulations. Connect a new cylinder as described in chap. 11.1.
Refillable CO₂ pressurised gas cylinder:
Close the cylinder valve and disconnect the CO₂ hose from the pressure regulator. Open the adjusting screw and release any pressure still present in
the pressure regulator until both pressure gauges indicate 0 bar. Loosen the connecting nut of the pressure regulator from the cylinder valve. Hand
over the reusable CO₂ pressurised gas cylinder for refilling.
If there is no filled reusable CO₂ pressurised gas cylinder available, you can also connect a disposable cylinder. Use the enclosed Allen key (size 6) to
remove the cylinder connection nut from the pressure regulator. The thread that comes free will fit the disposable CO₂ cylinder.
Connect the filled reusable CO₂ pressurised gas cylinder or the disposable CO₂ pressurised gas cylinder as described in chap. 11.1.

11. Technical data

Pressure regulator JBL PROFLORA CO₂ REGULATOR PROFESSIONAL:
Version V with pre-assembled thread adapter JBL PROFLORA CO₂ ADAPT U - M
Cylinder connection thread W21.8 x 1/14" to M10x1
Version U without pre-assembled thread adapter JBL PROFLORA CO₂ ADAPT U - M
Cylinder connection thread: M10 x 1
Pressure gauge cylinder pressure: 0 – 160 bar
Pressure gauge working pressure: 0 – 4 bar
Adjusting screw for working pressure
Precision needle valve
Connection thread for hose screw connection: 1/8"
Hose screw connection for hose 4/6 mm
Pressure regulator JBL PROFLORA CO₂ REGULATOR BASIC:
Version V with pre-assembled thread adapter JBL PROFLORA CO₂ ADAPT U - M
Cylinder connection thread W21.8 x 1/14" to M10x1
Version U without pre-assembled thread adapter JBL PROFLORA CO₂ ADAPT U - M
Cylinder connection thread: M10 x 1
Preset working pressure: approx. 2 bar
24
Precision needle valve
Connection thread for hose screw connection: 1/8"
Hose screw connection for hose 4/6 mm
Solenoid valve JBL PROFLORA CO₂ VALVE
Voltage: 12 V DC
Power consumption: 2 W
Hose screw connection outlet: for hose 4/6 mm
Inlet thread: 1/8"
Closed when currentless (NC)
Power supply unit:
Primary: 100 – 240 V AC, 47 – 60 Hz, 0.25 A
Secondary: 12 V DC, 0.3 A, 3.6 W
pH control JBL PROFLORA CO₂ CONTROL:
See separate operating instructions.
Disposal:
Components of your JBL PROFLORA CO₂ system which are marked with the adjacent symbol must not be disposed of with the normal household
waste. Please follow your local disposal regulations for electrical appliances.