Error
Display
Reason
Remedy
Solar array
Battery is not
Remove faulty
faulty or
being charged
connection /
wrong polarity
during the day
reverse polarity
LED is off
(Green LED off)
Programming Nightlight Light Function
You enter the programming mode with a long push on the button.
The programming menu structure is described on the follow page.
Mind that once you have entered the programming menu you can
exit it at the last item only. We therefore recommend that you
first note down your required settings in the check boxes besides
the menu structure and then do the programming in one go. This
makes programming easier and avoids errors. All programming
settings are stored in a non-volatile memory and remain stored
even if the controller was disconnected from the battery.
Testing Function
During the daytime the testing function of CMLNL can help the
user to verify correct installation or for troubleshooting a system
problem. Short pushing the button will light up the lamp which
is connected to the load terminals. The lights will be on in the
day for 3 minutes intervals. Within 3 minutes the lights can be
turned off via pushing button.
The lights can turned on repeatedly with pushing button besides
when the system is in LVD (load disconnect/red LED on). In LVD
this testing function is not valid.
If pressing the button cause a load disconnects (LVD) the light will
turn off.
33