Setting Up A Master-Slave Chain; Mains Connection - Renkforce DL-1008 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pin assignment of the DMX connection: Pin1 = earth / Pin2 = (-) / Pin3 = (+).
Never connect the earth pin GND to the casing earth of the effect light; this may result in interfer-
ence in signal transmission caused by ground loops.
b) Setting up a Master-Slave Chain
The effect light can be operated controlled by a DMX controller or in a master-slave chain. In that case,
the integrated controller of the master device controls the connected slave devices.
• Connect the DMX OUT (1) port of the master device to the DMX IN (2) port of the first slave device.
• Connect the DMX OUT (1) port of the first slave device to the DMX IN (2) port of the subsequent slave
device.
• Proceed as described above with all remaining slave devices.
• Plug an XLR plug with a terminating resistor into the DMX OUT (1) port of the last slave device (as de-
scribed in section "Connection of a DMX Controller").

9. Mains Connection

The mains socket to which the effect light is connected must be close to the device and easily
accessible to quickly separate the device from the mains voltage in case of an error.
Ensure that the voltage indication on the effect light matches the mains voltage of your power
supply. Never try to operate the device with any other voltage.
Do not let the mains cable come into contact with other cables.
Be careful when handling mains cables and mains connections. Mains voltage may cause
potentially fatal electric shock.
Make sure that no cables are lying around openly. Install cables professionally to prevent ac-
cidents.
• Connect the mains cable low-voltage plug to the mains connection (4) at the device.
• Plug the mains plug of the mains line into a grounded socket.
• Once the device is connected to the mains socket, it takes up operation.