Preliminary operations
•
Take away the packing
•
Before installation, check the appliance integrity. In case of doubt, do not use the
appliance and call the dealer.
Packing materials is for recycle, getting it in the specify container
•
Appliance positioning
•
The installation room should have :
−
A suitable floor for appliance weight. Should the existing construction not satisfy
this requirement, necessary measurements must be taken (I.e. a plate for the
distribution of the weight)
−
A suitable floor for appliance calorific radiation, which grants against fire risks.
The installation of the appliance should grant an easy access for the cleaning
−
operations of the appliance itself, as well as of gas exhaust ducts and of the
chimney.
A minimal distance from flammable materials (see security distances)
−
The room must be continuously ventilated according to the local rules.
−
FLOOR PROTECTION
The equipment has to be put on a refractory surface.
In case of flammable floor ( moquette, parquet ..) it
is necessary to put a refractory base ( stainless steel,
ceramic etc ) with the following dimensions :
Hold up in front ≥ 500 mm;
−
−
Hold up lateral ≥ 300 mm;
−
Hold up back
SECURITY DISTANCES
From NOT combustible object :
•
A > 500 mm B > 100 mm C > 100 mm
From combustible object and from principal
•
wall in reinforced concrete :
A > 1000 mm B > 200 mm C > 200 mm
•
The minimal distance between the appliance
and every combustible objects over it must be
least 1,5 mt
IT-GB-FR mod. 740-740 ECO-740/SA-740/SA ECO-740N/SA
≥ 100 mm
45/120
To measure from apparatus
external surface for every models
at