Original Bedienungsanleitung FUXTEC FX-IG13_de_en_fr_ita_rev04
16.5
Spark plug (LG R6TC)
•
Open and lift away the left top cover
•
Remove the spark plug cap
•
Loosen the spark plug using the spark
plug socket.
•
Visually inspect the spark plug
•
Remove carbon deposits with a copper
wire brush
•
Check electrode gap (0,7 -0,8mm)
•
Reassemble the spark plug in reverse
order
16.6
Transport
•
Secure the machine to prevent slipping
•
Do not let the fuel spill out of the fuel tank.
•
When the generator is placed on vehicle, the engine may not run.
•
During transport, protect the machine from excessive heat. If longer periods in an enclosed
vehicle the fuel may ignite due to overheating.
16.7
Storage
If the machine is stored for longer than 30 days:
•
Wait until the engine cools down sufficiently.
•
Allow the fuel from the tank into a suitable container (or let the machine run till it stops itself)
and store the drained fuel in a suitable container.
•
Clean and dry machine
•
Store in a dry, out of reach of children place
•
Cover the machine well and store it in a dry and clean place.
16.8
Disposal
Do not dispose the machine, machine components fuel and oil in residual waste. Contact
your local authorities for information regarding the available disposal options. When you
buy at your local dealer for a replacement unit, the latter is obliged to exchange your old.
31