Télécharger Imprimer la page

Operation; Start; Stop; Economy Mode - FUXTEC FX-IG13 Mode D'emploi

Masquer les pouces Voir aussi pour FX-IG13:

Publicité

Original Bedienungsanleitung FUXTEC FX-IG13_de_en_fr_ita_rev04
15.3

Operation

15.3.1

Start

Turn the fuel valve to position „ON"
Switch the Engine-switch to position „I"
ON
At cold start set the choke to position
„START".
At worm start (the engine was running and is
still warm) set choke to Position „RUN".
If the generator fails to start after 5 attempts,
pull choke to position "START" and try again.
If the engine runs smoothly set choke to
position „RUN"
Start the engine with the recoil starter:
Grip the handle and pill the recoil starter.
If the engine does not start, try again.
Normally start: 3-4 attempts
When starting with the recoil starter, the motor may recoil suddenly as it starts up,
resulting in hand injuries!
15.3.2

Stop

In case of emergency stop the generator directly with the ON-OFF switch
In normal circumstances switch off the generator as follows:
Shut down the connected devices and disconnect them from the generator.
To cool down let the engine running for a while without any loads.
Switch off the generator by putting the engine switch to position „0" OFF
At longer breaks:
To cool down let the engine running for a while without any loads.
Thereafter close the fuel cock by turning to position „OFF".
The engine runs until the remaining fuel is consumed in the carburetor.
Switch off the generator by putting the engine switch to position „0" OFF
15.4

Economy mode

At low power output can be switched with the ECO switch to energy saving mode
ECO switch on: The engine always runs at idle speed and consumes less fuel
At high power output and in DC mode the ECO switch must always be switched OFF
A T T E N T I O N