Why choose a rolling code transmitter instead of a fi xed one?
IRolling code transmitters are safer as they cannot be cloned and have over 200
million combinations that change with each transmission. Fixed code transmitters,
instead, have 1024 code combinations that do not change with each transmission.
The station does not recognise the transmitter. Why?
Check that you are using the same type of station and transmitter. It is possible to
check the type of transmitter used by the station from the main screen and change if
cf
necessary by setting the parameter
.
Technical Data
•Automation current: 230V - 50/60Hz.
•Primary transformer protection fuse: F5A/230V.
•24V accessory output protection fuse: T1A.
•Integrated receiver (433Mhz): maximum capacity 76 radio codes.
•Operating times: -20° +55°
•Maximum rated output of the motor: 500W
•Maximum power of the fl asher output: 40W
•Maximum power of the open gate signal output (SCA): 5W
30