Addition of radiocontrols
GB
•Before memorising a transmitter make sure that it is compatible with the type of
receiver that is integrated (the fi rst time the display shows r, if the receiver is in
rolling code mode, or f if the receiver is in fi xed code mode). The receiver can
memorise rolling codes type HCS300 STAGNOLI with billions of combinations or
fi xed codes type HT53200 with 13 bits or the fi xed part of a rolling code (28 bit
SN). It is possible to memorise up to 76 codes.
•Enter the menu agg. radioc., move over the wording display 1ch or 2ch and
select the channel that is to be added. Press ENTER, the wording press will ap-
pear to press the key that must be memorised. At this point the display shows the
wording ok if the operation has been done correctly, err if there are registration
errors or full if the receiver memory is full.
•An external antenna installed far from the ground, increases the visibility betwe-
en the transmitter and the receiver. The power of the receiver can be reduced if
metal parts or reinforced concrete are placed next to it.
Regulating
ttca
•
(automatic closing time)= this is the time from the when the gate is opened
fully to when it is closed automatically. If the photoelectric cell is engaged, the
ttca
time is counted from the time when the photoelectric cell is freed. The default
time set by Stagnoli is 10 secs and it can be regulated from 1 to 240secs.
tm 1
•
(motor working time)= this is the maximum work time of the motor when
opening and closing. For greater safety regulate this parameter so that it is slightly
above the time it really takes for the gate to complete a single manoeuvre. The de-
fault time set by Stagnoli is 120 secs and it can be regulated from 5 to 240secs.
aped
•
(pedestrian opening)= this is the length of the stroke stated in centimetres
of the partial opening, namely the pedestrian mode. The default value set by Sta-
gnoli is 70 secs and it can be regulated from 30 to 150.
rlap
•
(slowed stroke in opening)= the station slows down the stroke of the motor in
the end part of its opening phase. The default stroke set by Stagnoli is 0 cm and it
can be regulated from 0 to 70 cm. With
N.B: In slowing phase, the motor works with 1/3 of its nominal speed. In this
phase, the force, applied on the motor is reduced and not adjustable.
rlch
•
(slowed stroke in closing)= the station slows down the stroke of the motor in
the end part of its closing phase. The default stroke set by Stagnoli is 0 cm and it
can be regulated from 0 to 70 cm. With
N.B: In slowing phase, the motor works with 1/3 of its nominal speed. In this
phase, the force, applied on the motor is reduced and not adjustable.
WARNING: before setting the slowing phase check that the gate has been installed
correctly and that during the slowing down phases the motor has enough power
to complete the stroke. If this is not the case do not use slowing down functions. In
this phase, the motor has less power and the way this parameter is set can infl uen-
ce the level of safety of the system itself. When operating without encoder, slowing
24
rlap=0
there is no slowing down.
rlch=0
there is no slowing down.