Even if the safeties remain active ensure that there are no objects or people in the
GB
area of operation of the gate.
Read codes
It is possible to check if a code has already been memorised. Position yourself
on the wording
message
series of screens describing the code will be viewed:
•fi rst screen:
The fi rst letter indicates the manufacturer of the radio control, where
gnoli and
The second letter indicates the type of code, where
f
a fi xed code.
The last two indicate the code of the key that was pressed.
•second screen:
that follows (progressive from
transmitter in the memory. If the transmitter is not found in the memory the display
will show
•third and fourth screens: show the hexadecimal code of the transmitter.
Statistics screens
The control centre has four statistics screens that are viewed by keeping the key
ENTER pressed once the display is positioned on the main menu:
•fi rst screen:
of the gate in kilos.
•second and third screens:
vres undertaken.
•fourth screen: indicates the stroke in the memory.
Diagnostics screens
The station can recognise problems or alarms that can occur in the system there-
for it can signal some messages on the main display to allow the problem to be
identifi ed:
1 rf
= activation of the START command on the fi rst radio frequency channel.
2 rf
= activation of the START command on the second radio frequency chan-
nel.
sta
= activation of the START command on the terminal board input.
ped
= activation of the pedestrian entry command.
stO
= activation of the STOP command on the terminal board input.
phO
= activation of photoelectric cells input on the terminal board.
phA
= activation of the photoelectric cells input on the terminal board in the ope-
ning phase.
bar
= activation of the entry of the safety ribs.
swo
= activation of the entry of the limit stop on opening.
swc
= activation of the entry of the limit stop on closing.
am 1
= operation of the current meter sensor on the fi rst motor.
enc1
= operation of the sensor with encoder on the fi rst motor.
prg
= programming regulations or operations underway.
OK
= successful outcome of operation.
ERR
= unsuccessful outcome of operation.
full
= radio control memory full.
attendi
tout
= waiting time expired.
29
leggi codice
PREMI
(PRESS). Now press the transmitter key that must be checked, a
S r 01
- f 01
or
-
a generic manufacturer.
P_00
, where
----
.
H500
H
, where
= wait.
(read code), press ENTER, the display will show the
.
P
indicates the word "position" and the number
0
75
to
), indicates the position occupied by the
means Hercules motor and 500 the maximum weight
0000 0000
indicates the number of complete manoeu-
S
r
indicates a rolling code and
means Sta-