down is run with a time logic that is less precise than one with an encoder. Once
GB
this phase has been done, check the force of impact of the gate.
senc
(encoder sensitivity)= anti-crushing sensitivity of the motor with encoder
activated (
regulated from 0 to 99.
WARNING: In regulating this parameter remember that a low
tes greater anti-crushing sensitivity. Stagnoli advises setting this parameter with a
safety margin that is at least +10 compared with the maximum value shown on
the display in the second screen during the movement of the motor. At the end
of installation check that the force of impact is in compliance with the regulation
EN12453.
fm1a
(force of the motor in opening)= is the force of the motor stated in percen-
tage compared with the maximum force that the same can generate. The default
value set by Stagnoli is 5 and it can be regulated from 1 to 10.
fm1c
(force of the motor in closing)= is the force of the motor stated in percentage
compared with the maximum force that the same can generate. The default value
set by Stagnoli is 5 and it can be regulated from 1 to 10.
WARNING: the setting of these two parameters can infl uence the level of safety
of the system itself. At the end of installation check that the force of impact is in
compliance with the regulation EN12453.
brak
(braking current)= this is the current that the motor exercises in the gate
stopping phase. The default current set by Stagnoli is 5 and it can be regulated
from 0 to 10.
trel
(N.O. exit activation time)= it is the N.O. exit activation time from the receipt
of the motor movement command (see
li is 2 secs and it can be regulated from 1 to 240secs.
tdec
(deceleration time)= it is the time used by the motor to slow down the stroke
when opening and closing with
comes about automatically as the encoder reads the speed and position of the
gate. The default time set by Stagnoli is 1 sec and it can be regulated from 1 to
4 secs.
Functions
da
(opening direction)= indicates the opening direction of the gate that is viewed
on the main screen after the indicating the type of receiver (
To change the gate opening direction go to
parameter from
ca
(automatic closing)= automatic closing of the gate after it has opened com-
pletely.
ca=0
function not enabled.
ca=1
function enabled.
Set the
ning and the start of automatic closing. N.B: If
25
en=1
function). The default value set by Stagnoli is 50 and it can be
0
1
to
depending on the desired direction.
ttca
regulation to customise the time that must pass from the end of ope-
sv
function). The default time set by Stagno-
en=0
function. If the function
da
on the display and change the
ca=1
senc
value indica-
en=1
, this regulation
r|-00
r-|00
or
2p=0
and
, the command to
).

Publicité