Extraflame MIX02 Mode D'emploi page 48

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 52
DISPLAY IN "ROOM PROBE" MODE:
TSET (t°
) = temperature set (day t°, night t°, anti-freeze t°)
c
TEXT (t°
) = temperature read by the external probe
c
TCAL = system fl ow temperature calculated by the software
TMAN = temperature read by the fl ow probe
TAMB = temperature read by the internal room probe
Keys 1 and 2 : Method to enable Chrono, day comfort t°, anti-freeze t° anti-freeze, night t°
Keys 5 and 6 : Setting the temperature of the relative: day t°, anti-freeze t°, night t°. To select the modes, use the keys 1 and 2.
Keys 1 and 2 : Method to enable Chrono, day comfort t°, anti-freeze t° anti-freeze, night t°
Keys 5 and 6 : Setting the temperature of the relative Chrono, day comfort t°, anti-freeze t° anti-freeze, night t° To select the
modes, use the keys 1 and 2.
USER MENU
CLOCK ADJUSTMENT
This menu allows to adjust the clock.
Press button 1(menu) for a few seconds to access the menu
and select "USER" with keys 1 and 2 and confi rm with key 3 (ok)
Using the buttons 1 (menu) and 2 select " SET CLOCK" and then
press button 3 (ok) to confi rm
Using buttons 1(menu) and 2 select the value to be adjusted
among those available: HOUR, MINUTES, SECONDS and DAY OF
THE WEEK
Adjust the parameter selected using buttons 5(-) and 6(+)
Press button 4 (esc) to confi rm and escape
DATE OF REGULATION
This menu allows to adjust the clock.
Press button 1(menu) for a few seconds to access the menu
and select "USER" with keys 1 and 2 and confi rm with key 3 (ok)
Using the buttons 1 (menu) and 2 select " SET DATE" and then
press button 3 (ok) to confi rm
Using buttons 1(menu) and 2 select the value to be adjusted
among those available: DAY, MONTH and YEAR
Adjust the parameter selected using buttons 5(-) and 6(+)
Press button 4 (esc) to confi rm and escape
WEEKLY PROGRAMMING SELECTION
This menu allows to regulate the weekly programming
Press button 1(menu) for a few seconds to access the menu
and select "USER" with keys 1 and 2 and confi rm with key 3 (ok)
Using the buttons 1 (menu) and 2 select " MODE" and then
press button 3 (ok) to confi rm
Using buttons 5(-) and 6(+) select the day and time for the
weekly programming
USER MENU
TIME
DATE
SET (T°C)
TMAN (T°C)
TCAL
TAMB
TEXT
Press button 4 (esc) to confi rm and escape
INSTALLER MENU
INSTALLER PARAMETERS
Press button 1(menu) for a few seconds to access the menu and
select "INSTALLER" with keys 1 and 2 and confi rm with key 3 (ok)
Using buttons 5 and 6 enter the password 15
Press button 3 (ok) to confi rm
tables and parameters menu
TYPE OF REGULATION
Fixed point (type 0)
Climatic with external probe (type 1)
Climatic with external probe and room probe (type 2)
SET SYSTEM (type 1 and 2 only)
Radiant panels
Fan coils
Radiators
Hot air ovens
Parameters (diff erent tables in relation to the type of
regulation)
FIXED POINT REGULATION PARAMETERS
Pf1
Flow temperature
Pf2
Safety fl ow temp.
Pf3
Valve opening time
CLIMATIC REGULATION PARAMETERS WITH EXTERNAL
PROBE
Pc1
System factor
Pc2
Safety fl ow temp.
Pc3
Maximum fl ow temp.
Pc4
Minimum fl ow temp.
VIEW
PF
SE
SA
PA
VE
RA
AE
0 - 80
0 - 80
0 - 480
0.1 - 4
0 - 80
0 - 80
0 - 80
47