HOMOLOGATIONS
according to
Regulation ECE / ONU
The
ECE / ONU Regulation
equivalent to the European Directive 95/56/EC and is also recognised in non EEC countries
such as, for example, Russia, Japan, etc.
This regulation includes immunity to interference tests and the EMC tests in accordance with
the
ECE / ONU Regulation
The
central unit is type-approved as an ALARM system according to
MED 11.3
no.
ECE / ONU
R 10
The electronic siren
electromagnetic compatibility (interferences and noises) according to
no.
, and is also recognised in non EEC countries such as, for example, Russia, Japan, etc.
R 10
with the number:
The type-approval also includes the
The
WARNING:
MED 11.3
brochure specifications indicated in the compliance statement and in the working instructions.
Any product tampering or any changement in the a.m. features as well as any intervention in the
working way or in the connection done without complying with the installing instructions can
modify these conditions according which the product is homologated to, which can have
consequences on the further product selling.
MED 11.3 central unit
Feeding voltage:
Current absorption:
(average values)
Temperature range:
Place:
Protection:
Direction indicators output with relay on 2 wires:
Direction indicators output on a single wire:
Timed / excludable / fixed status output:
Alarm output:
(optional)
CHD 400 KEYS
Temperature range:
Life:
Protection:
Rolling-Code combinations:
(Electronic siren) - (optional)
SIR 010 SIREN
Feeding voltage:
Current absorption (mean values):
Temperature range:
Protection:
SIR 050.NA SIREN
(Electronic self-powered siren, with integrated buzzer) - (optional)
SIR 050 SIREN
Feeding voltage:
Current absorption (mean values):
Temperature range:
Protection:
(Electronic siren) - (optional)
Sirena SIR 060
Feeding voltage:
Current absorption (mean values):
Temperature range:
Protection:
The
MED 11.3
no.
no.
97
no.
.
10
with the number:
,
SIR 010 SIR 050
n.
E
10R - 03 6414
3
SIR 060
central units are projected and set according to the product technical
TECHNICAL FEATURES:
(Electronic siren, with integrated buzzer) - (optional)
central unit is type-approved as an ALARM system
with the number:
R 97
, referring to functioning and safety of alarm systems is
n.
E
10R - 04 6459
3
and
SIR 050.NA
electronic siren.
(nominal) 8 / 16 Vdc
12 Vdc
< 1
(
activated system, first 8 days
2 mA
<
(
following days
10 mA
from
- 40 °C
cockpit
(IEC 529 1989) DIN 40050 EN 60529
IP 40
+
10 A 10 A
NEGATIVE
0.7 A
0.7 A
from
- 40 °C
unlimited
(IEC 529 1989) DIN 40050 EN 60529
IP 40
more than
18 billions of billions
(nominal) - 8 / 16 Vdc
12 Vdc
at rest -
0 mA
from
- 40 °C
(IEC 529 1989) DIN 40050 EN 60529
IP 67
(nominal) - 8 / 16 Vdc
12 Vdc
at rest -
1 mA
from
- 40 °C
(IEC 529 1989) DIN 40050 EN 60529
IP 67
(nominal) - 8 / 16 Vdc
12 Vdc
at rest -
0 mA
from
- 40 °C
(IEC 529 1989) DIN 40050 EN 60529
IP 66
n.
E
3
are type-approved concerning the
Regulation ECE / ONU
) <
10 mA
to
+ 85 °C
impulse
- 0.7 A
to
+ 85 °C
activated system
0 mA
to
+ 85 °C
activated system
1 mA
to
+ 85 °C
(on alarm)
300 mA
to
+ 85 °C
97R A - 01 6002
Regulation
)
(at rest)
19