DOLD SAFEMASTER BN 3081 Mode D'emploi page 16

Masquer les pouces Voir aussi pour SAFEMASTER BN 3081:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Application Examples
DC24V +
-
A1
A2
Emergency-stop module
e.g. LG5925
A1
A3
A4
A2
A1
A3
A4
A2
A1
A3
A4
A2
M8374_a
Contact multiplication with several extension moduls 1-channel;
suitable up to SIL3, Performance Level e, Cat. 4, if a short circuit fault
exclusion can be made for the wiring according to EN ISO 13849-2.
E. DOLD & SÖHNE KG • D-78114 Furtwangen
e-mail: dold-relays@dold.com • internet: http://www.dold.com
S11
S12
S21
S22
S33
S34
13
23
...
81
BN3081
Nr.1
...
14
24
82
13
23
...
81
BN3081
Nr.2
...
14
24
82
13
23
...
81
BN3081
Nr.n
...
14
24
82
DC24V +
-
A1
Emergency-stop module
e.g. LG5925
A1
A2
-
DC24V
A3
+
A4
A1
A2
-
DC24V
A3
+
A4
A1
A2
-
DC24V
A3
+
A4
M8373_a
Contact multiplication with several extension moduls 2-channel
with cross fault monitoring;
suitable up to SIL3, Performance Level e, Cat. 4
PO Box 1251 • Telephone (+49) 77 23 / 654-0 • Telefax (+49) 77 23 / 654-356
16
A2
S11
S12
S21
S22
S33
S34
13
23
...
81
BN3081
Nr.1
...
14
24
82
13
23
...
81
BN3081
Nr.2
...
14
24
82
13
23
...
81
BN3081
Nr.n
...
14
24
82
BN 3081 / 25.09.18 en / 022A