Condition
Motor fails to run.
Pressure Relief Valve opens to
discharge grease.
PowerLuber fails to dispense grease.
PowerLuber continues to lose prime.
Battery fails to take a charge.
Form 422014
www.treboux.ch info@treboux.ch
TROUBLESHOOTING
Possible Cause
- Battery needs charging.
- Faulty wiring to motor.
- Blocked Line.
- Blocked Bearing
- Blocked Grease Fitting.
- Grease tube assembly is out of grease.
- Loss of prime.
- Ball check item 22 is not functioning.
- Air may be trapped in several locations
- Follower may be binding in grease
tube assembly.
- Charger may not have power.
- Battery may be bad.
+41 (0)33 221 98 44
Corrective Action
Recharge battery.
Remove battery, disassemble handle and
check wiring for loose connection.
remove or clean obstructions.
Check that grease tube assembly has grease.
Repeat priming operation.
Remove Items 22 and clean and
inspect ball seat area.
repeat priming instructions.
Replace grease tube assembly Item 9.
Check that receptacle has power.
Replace battery.
Page Number - 9