- Now on the thermostat press and maintain the edition key
( ) during 5s, then the parameter « INI » must be
displayed.
The thermostat will send now the radio configuration signal
to the receiver.
- After few seconds the thermostat and receiver should exit
by their self the RF init mode, this is the normal procedure
to confirm a correct pairing.
- Now you can check the RF distance, go to the room
which must be regulated. Put your thermostat on the final
position (On the wall or table...), then put the thermostat in
Comfort mode (setting temperature position 37°C). Close
the door and go to the receiver to check if the new status of
the thermostat has received. (The heating is generally
showed by a Red LED on the receiver).
- Now return to the thermostat and switch off it. Check on
the receiver again if it's also switched off (The red LED
must be turned off)
If the RF signals were received correctly, adjust your
setting temperature as you want.
If the RF signals weren't received correctly, check the
installation (Receiver position, distance...) or restart the RF
init rules to be sure.
* To make the installation easier it will be better to have the
thermostat near to the receiver during the configuration
mode. (A minimal distance of > 1meter must be respected)