USER GUIDE
RF basic thermostat WFHTRF 01 (20033)
MODES DESCRIPTION
-
Radio frequency RF thermostat (433.92 Mhz) specially designed for water
floor heating.
-
Personal code on each product.
-
Equipped with a switch to select 3 different operating modes:
-
Comfort (The thermostat follow the setting temperature)
- Off
-
Night reduction (The thermostat follow the setting temperature – 4°C)
-
To be used only with ours receivers.
LED Indicator.
Batteries
GB
Select
mode.
Room
setting.
-
RADIO CONFIGURATION MODE
•
Turn the thermostat in Off position.
•
To assign (*) the RF thermostat with the receiver you must put the
receiver in "RF init" mode (please refer to the receiver leaflet).
•
After you have just made the thermostat in
The thermostat sends its configuration address by radio signal. (The
thermostat LED blinks green)
•
You can check the good signal reception on the receiver (please refer to
the receiver leaflet)
•
Now your thermostat is correctly assigned with the receiver, place your
thermostat in the room need to be regulated.
* (To configure correctly your thermostat with the receiver you should place the
thermostat near to the receiver during the RADIO CONFIGURATION)
LED INDICATOR
Red:
- Heating indication (During consign adjustment)
Red Blinking:
- 1 second cycle => Low batteries indication.
Green blinking:
- Radio transmission (1 flash by transmission)
TECHNICAL CHARACTERISTICS
Measured temperature
0.1°C (or 0.2°F)
precision
Operating temperature
0°C - 50°C (or 32°F – 122°F)
Setting temperature range
5°C – 30°C (or 41°F - 86°F)
Regulation
Proportional band 15min for 2°K
characteristics
Electrical Protection
Class II - IP30
Power Supply
2 x 3V (CR2430)
Battery operated life
~ 2 years
Radio frequency
433.92 MHz, <10mW.
CE. EN 300220-1, EN 301489-1
certifications
(Radio frequency certifications)
Soft version
V 2.0x
or
mode.
PPL IMP 1131B