Servicing
Servicing of the unit should be carried out once annually by the
1. Check high-pressure hoses, device connecting line and plug
for damage.
2. Check the inlet valve, outlet valve and lter for wear.
Inspect the high-pressure hose visually for any notches or bulges, in
particular at the transition in the ttings. It must be possible to turn
the union nuts freely.
The risk of damage rises with the age of the high-
i
pressure hose. Wagner recommends replacing high-
pressure hoses after 6 years.
Switch the unit OFF.
Before all repair work: Unplug the power plug from
the outlet.
Item 1) from the relief valve handle (2).
2. Remove the relief valve handle (2) and cam base (3).
4. Ensure that the seal (5) is seated correctly, then screw the new
valve housing (4) completely into the lter block (6). Tighten
securely with a wrench.
5. Align the cam base (3) with the hole in the lter block (6).
Lubricate the cam base with grease and slide on the cam base.
6. Bring the hole in the valve shaft (7) and in the relief valve
handle (2) into alignment.
7. Insert the grooved pin (1) to secure the relief valve handle in
position.
4
3
2
1
5
7
GB
1. Remove the four screws in the front cover and then remove
the front cover.
Danger of crushing - do not reach with the ngers or
tool between the moving parts.
2. Turn the pressure control knob to minimum pressure. The
4. Slowly turn the pressure control knob clockwise to increase
the pressure. The crankshaft/slider assembly will begin to
move very slowly.
5. When it reaches the bottom, dead-center of its stroke, turn
the pressure control knob back to minimum pressure. The
crankshaft/slider assembly should stop.
7. Pull o clamp on suction tube and remove return hose.
pressure lter.
9. Turn the knob on the side of the cart clockwise to unlock the
cart. Tilt the cart backwards until it locks into place.
10. Loosen and unscrew inlet valve housing (2) from the lower
housing (3) with light blows from a hammer or unscrew with
an adjusting wrench.
(7), inlet valve ball (8) and upper ball guide (9).
12. Clean all the parts with the corresponding cleaning agent.
Check the inlet valve housing (2), inlet valve seat (7) and inlet
valve ball (8) for wear and replace the parts if necessary. If the
worn inlet valve seat (7) is unused on one side, install it the
other way around.
13. Carry out installation in the reverse order.
seating in the inlet valve housing (2).
6
36
1
3
9
8
7
6
5
4
2
Repairs at the unit