English
» Set temperature reached
» Key Lock
» LED brightness adjustment
The operation of the device is controlled by a
O / 5s
central thermostat or programmable thermostat.
On / 1s
When the set temperature is reached, the fan
stops and the ventilation indicator LEDs switch off.
The operating condition reached is signalled by
the control by the intermittent switching on of
the stand-by LED:
1 second on and 5 seconds off, to indicate that the
fan is stopped due to external control.
In order to avoid that the fan speed, once selected,
can be modified by other people, it is possible to
activate the "Key Lock" function.
Set the control to ON.
Press and hold the
simultaneously for 5 seconds.
All speed LEDs flash twice to confirm the operation.
Repeat the operation to unlock the control
buttons.
During stand-by the brightness of the LEDs will be
halved compared to the chosen value.
Put the control in stand-by mode.
Press and hold the
simultaneously for 5 seconds.
The LEDs light up at maximum brightness.
Use the
the brightness of the LEDs to the desired value.
6
and
buttons to increase or decrease
and
buttons
and
buttons