SECTION 7 – USER SERVICING INSTRUCTIONS (MAINTENANCE)
7-1.
Routine Maintenance
Disconnect power before maintaining.
�
See equipment more often if used in severe conditions.
�
Use a vacuum equipped with a HEPA filter to clean inside unit.
� = Check
Daily
� Filter Monitoring Light
Every
Month
� Outer Surfaces
Every 3
Months
� Unreadable Labels
Every 6
Months
� Inside Unit
*To be done by Factory Authorized Service Agent.
◇ = Change
� Free Movement Of Col-
� Collection Hose And
lection Hose
Nozzle Stay In Position
��Motor Brushes
�
Expected brush life is
about 600 working
hours.
��Filter (Sections )
�*Motor Bearing Lubrica-
tion. Grease Bearings
Every 5500 Hours Of
Operation.
� = Clean
� = Replace
� Collection
Hose
�Inner Surface Of
Optional Nozzle
Section 7-2, Section
7-3