Section 5 - Installation; Serial Number And Rating Label Location; Selecting A Location - Miller FILTAIR 130 Manuel Du Propriétaire

Masquer les pouces Voir aussi pour FILTAIR 130:
Table des Matières

Publicité

5-1.

Serial Number And Rating Label Location

The serial number and rating information is located on the back of the unit. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
5-2.

Selecting a location

SECTION 5 – INSTALLATION
1
18 in.
(460 mm)
LocFiltair130 2016-02
2
Only qualified persons should in-
stall, operate, maintain, and repair
this unit.
Installation must meet all National,
State, and Local Codes - have only
qualified
installation.
Do not move or operate unit where
it could tip.
Do not use this equipment to sup-
port personnel, large tools, or oth-
er material.
Special installation may be re-
quired where gasoline or volatile
liquids are present - see NEC Ar-
ticle 511 or CEC Section 20.
1 Lifting Forks
2 Locking Casters
3
3 115
Volt,
15
Receptacle
4 Input Power Cord
Use casters or lifting forks to move unit.
4
If using lifting forks, extend forks beyond op-
posite side of unit.
Position unit near the welding operation and
close to 115 volt AC receptacle but away
from obstructions that may restrict move-
ment of the fume collector or collection hose.
A 115 volt AC, 15 amp individual
branch circuit protected by time delay
(type D) fuses or circuit breaker is
required.
245 353
persons
make
this
Amp
AC
Grounded
OM-244785 Page 17