5-3.
Tipping
5-4.
Preparing Unit For Operation
1
2
245 353-F
OM-244785 Page 18
5
4
Do not move or operate unit where
it could tip.
Do not move unit with extraction
arm extended or unit may tip.
Do not move unit by pulling on ex-
traction arm or equipment may tip.
Use handle on fume extractor to
move unit.
Do not use this equipment to sup-
port personnel, large tools, or oth-
er material.
Do not use the fume extraction
equipment unless you are sure it is
6
correctly assembled and working
properly.
1 Connection Port
2 Collection Hose
3 Nozzle (Optional) - Not Shown
4 Caster w/Brake
5 Latch
7
6 115
Volt,
15
Receptacle
7 Input Power Plug
Insert the stub end of the collection hose into
the connection port. Be sure the hose is se-
curely installed.
Connect optional nozzle to other end of col-
lection hose.
Verify all eight latches are closed and pro-
vide a secure attachment.
Lock caster brackets to keep fume extractor
in desired location.
Connect power cord to power supply. A 115
volt AC, 15 amp individual branch circuit pro-
tected by time delay fuses or circuit breaker
is required.
�
Set Air Flow control at level 6 before
starting unit. After unit starts, reduce
air flow to desired level (see Section 6-
1).
Select 12 AWG extension cord for distances
up to 50 ft (15 m) or 10 AWG extension cord
for distances up 100 ft (30 m).
Amp
AC
Grounded