INSTALLATION
GB
EQUIPMENT SUPPLY
The equipment already includes a power cable for AC supply. For connections to an AC supply see fig.2.
Before powering up the battery charger check that the power supply voltage, described on the rating la-
bel, corresponds to that supplied by the AC supply source.
A 2 pole switch must be installed in the electrical circuit for the sole use of switching the equipment ON
& OFF. The insulation between the contact points of the connections of the AC supply must be at least 3
mm. The connections to the AC supply must be carried out according to local electrical codes.
WARNING: before connecting or disconnecting the cables from the electrical terminals of the bat-
tery charger, make sure that the equipment is disconnected from the AC mains and the batteries.
WARNING: in cases where the power supply cable could be damaged, have this changed by a
"Quick
®
" service centre. In order to avoid accidents, the equipment must only be opened by au-
thorised personnel.
FIG.2
5 cm
5 cm
5 cm
BATTERIES
To access the output terminals it is necessary to remove the cover by loosening the two screws which
hold it on (see fig. 1 Part A). Before making the connections to the cables from the battery, loosen or re-
move the cable clamps by loosening the screws which fix it to the base (Fig.1 Part B).
WARNING: during charge, batteries can generate explosive gases, therefore avoid sparks or naked
flames. Provide adequate ventilation to the battery area whilst charging.
WARNING: before connecting the batteries check the terminals of the cables from the battery.
Reversing the terminals, could seriously damage the battery charger even if protected by fuses.
18
SLAVE B
5 cm
Battery switches
battery
n° 3
SLAVE A
MASTER
battery
battery
n° 2
n° 1
Blue
Neutral
Earth
Yellow
Green
Live
Brown