OBJ_BUCH-1347-001.book Page 23 Friday, January 21, 2011 10:30 AM
Supervise children. This will ensure that
children do not play with the charger.
Children or persons that owing to their
physical, sensory or mental limitations or to
their lack of experience or knowledge, are
not capable of securely operating the charg-
er, may only use this charger under supervi-
sion or after having been instructed by a re-
sponsible person. Otherwise, there is
danger of operating errors and injuries.
Products sold in GB only: Your product is fitted
with an BS 1363/A approved electric plug with
internal fuse (ASTA approved to BS 1362).
If the plug is not suitable for your socket outlets,
it should be cut off and an appropriate plug fit-
ted in its place by an authorised customer serv-
ice agent. The replacement plug should have the
same fuse rating as the original plug.
Technical Data
Digital Laser Rangefinder
Article number
Distance measurement
Measuring range
Measuring accuracy (typically)
Lowest indication unit
Indirect Distance Measurement and Vial
Measuring range
Grade measurement
Measuring range
Measuring accuracy (typically)
Lowest indication unit
General
Operating temperature
Storage temperature
Allowable charging temperature range
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter (at 25 °C) approx.
– at 10 m distance
– at 80 m distance
Bosch Power Tools
The severed plug must be disposed of to avoid a
possible shock hazard and should never be in-
serted into a mains socket elsewhere.
Product Description and
Specifications
Please unfold the fold-out page with the repre-
sentation of the measuring tool and leave it un-
folded while reading the operating instructions.
Intended Use
The measuring tool is intended for measuring
distances, lengths, heights, clearances, grades
and for the calculation of areas and volumes.
The measuring tool is suitable for measuring in-
doors and outdoors.
GLM 80
Professional
3 601 K72 3..
A)
0.05–80 m
B)
±1.5 mm
0.1 mm
–60° – +60°
C)
0° –360° (4x90°)
D)
±0.2°
0.1°
E)
–10 °C...+50 °C
–20 °C...+50 °C
+5 °C...+40 °C
90 %
2
635 nm, <1 mW
6 mm
48 mm
2 609 140 807 | (21.1.11)
English | 23
GLM 80+R60
Professional
3 601 K72 3..
A)
0.05–80 m
B)
±1.5 mm
0.1 mm
–60° – +60°
C)
0° –360° (4x90°)
D)
±0.2°
0.1°
E)
–10 °C...+50 °C
–20 °C...+50 °C
+5 °C...+40 °C
90 %
2
635 nm, <1 mW
6 mm
48 mm