5. Insert the two screw covers in the two fixing
holes in the outer grille.
6a. If wiring from the rear, remove the fan's
terminal cover and rear entry knockout. Feed
the cable through the rear cable entry.
6b. If wiring from above, remove the fan's
terminal cover. Make a hole through the
grommet suitable to provide a tight fit around
the cable sheath and feed the cable through
the top cable entry and grommet.
7. Hold the fan assembly to the inside of the wall
so that the spigot is inserted into the wall
duct.
8. Mark the position of the two fixing holes in the
top left and bottom right corners.
9. Remove the fan assembly, drill the holes and
insert anchor fixings appropriate to the type of
wall.
10. Reposition the cable and fan assembly as
before and screw securely in place. Do not
over tighten screws.
Note: For particularly difficult installations, it is
possible to secure the fan with a combination of screw
and ladder strip fixings.
Wire the electrical connections
1. Wire the switch cable into the terminal
connections as shown in Fig. E.
2. If the fan is wired from above, ensure the
outer sheath of cable is retained in the
labyrinth, see Fig. C.
3. Refit and secure terminal cover.
4. Ensure top cable entry grommet is correctly
fitted
5. Refit the back draught shutter/grille assembly
by sliding the grille back over the release
catches, press in on the side wall of the grille
as shown in Fig. H and locate the guides on
the grille, inside the fan backplate. The
catches on the backplate will locate and
secure the grille.
Ensure the Grille fits flush with the fan
assembly.
6. Switch off the mains electricity supply and
remove fuses.
7. Connect the cable from the isolation switch to
the electrical supply wiring.
8. Replace the fuses and switch on the mains
electricity supply.
For fixed wiring circuits the protective fuse for the
appliances must not exceed 5A.
Operating the fan
These fans are single speed and non-reversible
(extract only).
The shutters have a time delay of up to 1
minute on opening and up to 3 minutes on
closing. Activated by operation of the switch,
the delay ensures quiet operation (except
GXC6EC model).
For Australia Only:- Warning – Children should
not play with the appliance. Young children and
the infirm should be supervised.
GXC6EC
The fan is operated by an integral pull cord.
To switch on, pull down the cord and release it.
Repeat to switch off.
GX6EC
The fan is operated by a remote switch.
Trickle ventilation
Trickle ventilation is equivalent to that provided by an
airbrick or similar device.
1. Remove
the
assembly (see "Mounting the fan in the hole"
section).
To allow trickle ventilation
2. HOLD
THE
OPEN.
3. Push down firmly on the trickle vent catch
until it clicks into position then release the
shutter vanes, see Fig. F. item 6.
To fully close the shutters and stop any back draught
4. Pull the trickle vent catch towards you until it
clicks into position.
5. Refit the back draught shutter/grille assembly,
see "Wire the electrical connections" section,
ensuring that the actuator lever is in the "fully
down" position.
Maintenance
A QUALIFIED ELECTRICIAN MUST CARRY OUT
ALL CLEANING.
NOTE: THE FAN WILL CONTINUE TO OPERATE
WITH THE INNER GRILLE REMOVED HENCE IT
MUST BE ISOLATED COMPLETELY FROM THE
MAINS BEFORE ANY WORK IS CARRIED OUT.
1. Before cleaning, isolate the fan completely
from the mains electricity supply. Allow 3
minutes for the impeller to stop rotating
and
the
powered
Cleaning on the GXC6EC can begin once
the impeller has stopped rotating.
2. Remove
the
assembly by pressing the release catch
located on the side of the unit with a 6mm
screwdriver or a coin, whilst pulling the grille
forward. To remove the back draught shutter,
lay face down and pull the shutter forwards,
see Fig. G1 and Fig. G2.
3. To clean the impeller, wipe it with a damp, lint
free cloth. Do not use strong detergents or
chemical cleaners.
4. Clean the back draught shutter and grille in
warm soapy water. Do not use strong
detergents or chemical cleaners.
5. Thoroughly dry the back draught shutter and
grille and refit the back draught shutter to the
grille by placing into position and pushing
down until it clicks into position, see Fig. G3
and Fig. G4.
back
draught
shutter/grille
SHUTTER
VANES
shutter
to
back
draught
shutter/grille
FULLY
close.
9