Installation
Install the bubble machine in a well-ventilated area. Never cover the unit's vents. In order
to guarantee adequate ventilation, allow a free air space of at least 20 cm around the sides
and top of the unit. Install the device out of the public area. Please consider that liquid may
be spitted during operation around the device. The resulting slippery surface can cause
accidents. Position output of bubbles away from persons. The minimum distance should
be 1.5 m. Only install the machine on scratch resistant and water resistant surfaces.
Please make sure that the inclination angle does not exceed 15°.
When installing the device, make sure there is no highly-inflammable
Material (decoration articles, etc.) within a minimum distance of 0.5 m.
This device is constructed for a standing installation only. If the device is to be installed
overhead, the following safety instructions are binding:
Please consider the EN 60598-2-17and the respective national norms during
the installation! The installation must only be carried out by an authorized
dealer!
The installation of the device has to be built and constructed in a way that it can hold 10
times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an
appropriate catch net. This secondary safety attachment must be constructed in a way that
no part of the installation can fall down if the main attachment fails.
When rigging, derigging or servicing the device staying in the area below the installation
place, on bridges, under high working places and other endangered areas is forbidden.
Washer
M8 Safety eyelet
Dip switches
OFF
ON
1 2
3
4
5
6
7
8
9
SW .
1 4 2
8 32
16
64 128
256
CH.
DANGER OF FIRE!
DANGER TO LIFE!
4
Washer
Tightening Screw