1.5 Potential problems and how to tackle them
Kind of operating problem
Odour formation
Too little heating performance
Possible reasons
Curing of the applied preventive
lacquer.
Steaming oil remains.
We chose too little
performance
Chimney draught is slight
Too long and leaky smoke tube ♦
Leakage at the door glass
Usage of wet wood.
-19-
Solution
Operate the fire-place on a low
heating level according to the
instructions manual for a few
hours. Then heat up for maximal
performance for a few hours.
Have the heating
requirement of the room
examined by an expert
Chimney draught shall be at
least 10 Pa
Check the tightness of your
chimney and also that the
doors of other fire-places
leading to the same chimney
are closed and sealed
properly. Make sure that the
chimney-cleaning joints are
sealed properly.
All the smoke tube joints
must be well sealed and
fireproof-isolated
Check the sealing, close the
door properly. May have to
have the tightening flap
renewed.
Use well dried wood only.